Waste Water & Effluents
Instruments for monitoring the aeration-process, nitrification and de-nitrification; chlorination and de-chlorination; as well as the final discharge into the environment.
Chlorine
Analyzer AMI Codes-II
Colorimetric process analyzer (DPD-method) for measurement and dosing control of disinfectants such as free chlorine, hypochlorus acid, chlorine dioxide, ozone, bromine, iodine and monochloramine.

  • For the continuous online determination of disinfectants based on the DPD colorimetric method (EN ISO 7393-2; APHA 4500 Cl-G.
  • Also applicable for water containing additives like corrosion inhibitors, cyanuric acid and antiscalants.
  • Measurement values: Free chlorine, chlorine dioxide, bromine and iodine, monochloramine or ozone.
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • Integrated pH measurement with temperature compensation (available as option).
  • All usual dosing devices for disinfectants and pH control can be connected either through relays or analog output signals. Two independent controllers can operate simultaneously.

AMI Codes II(Data Sheet)Flyer AMI Codes II

Analyzer AMI Codes-II TC
Colorimetric process analyzer (DPD-method) for measurement and dosing control of total chlorine and calculation of dichloramine.
For the continuous online determination of disinfectants based on the DPD colorimetric method (EN ISO 7393-2; APHA 4500-Cl G).

  • Measurement values : total chlorine 1, total chlorine 2, dichloramine, flow and if installed pH and temperature.
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • Integrated pH measurement with temperature compensation (available as option).
  • All usual dosing devices for disinfectants and pH control can be connected either through relays or analog output signals. Two independent controllers can operate simultaneously.
  • Seperate chemical cleaning module available as accessor

AMI Codes II(Data Sheet) Combined chlorine Archiv Des Badewesens

AMI Codes II CC
Colorimetric process analyzer (DPD-method) for measurement and dosing control of disinfectants such as free chlorine, monochloramine, total residual chlorine and combined chlorine.

  • For the continuous online determination of disinfectants based on the DPD colorimetric method (EN ISO 7393-2; APHA 4500-Cl G).
  • Measurement values : free chlorine, monochloramine, total residual chlorine, combined chlorine, flow and if installed pH and temperature.
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • Integrated pH measurement with temperature compensation (available as option).
  • All usual dosing devices for disinfectants and pH control can be connected either through relays or analog output signals. Two independent controllers can operate simultaneously.
  • Seperate chemical cleaning module available as accessory.

AMI Codes II(Data Sheet)Flyer AMI Codes II Cc LowCombinedchlorine Archiv-Des-Badewesens

Analyzer AMI Codes-II CC
Chematest 25
Hand-held instrument for the determination of disinfectants, dissolved iron, dissolved aluminium, pH-value and ORP/redox-potential.

  • Photo- and pH-combimeter with state of the art microelectronics and clearly arranged display.
  • Well-devised analytical set in portable case.
  • Choice between routine and expert mode.
  • Determination of pH-value and ORP/redoxpotential by maintenance-free electrodes.
  • Determination of disinfectants with Oxycon reagents following the DPD method
  • Determination of free and bound chlorine, chlorine dioxide, ozone, iodine, bromine, cyanuric acid, dissolved iron, dissolved aluminium, pH-value and ORP/redoxpotential.

Chematest 25(Data Sheet)Flyer Chematest 25

Chematest 20S
Hand-held instrument for the determination of disinfectants, dissolved iron, dissolved aluminium and pH-value.
Photometer with state of the art microelectronics and clearly arranged display.

  • Well-devised analytical set in portable case.
  • Photometric determination of pH-value with phenolred.
  • Determination of disinfectants with Oxycon reagents following the DPD method.
  • Determination of free and bound chlorine, chlorine-dioxid, ozone, iodine, bromine, cyanuric acid, dissolved iron, dissolved aluminium and pH-value.

Chematest 20s(Data Sheet)Flyer Chematest 20S

Chematest 20N
Hand-held instrument for the determination of disinfectants, dissolved iron, dissolved aluminium and pH-value.

  • Photometer with state of the art microelectronics and clearly arranged display.
  • Well-devised analytical set in portable case.
  • Photometric determination of pH-value with phenolred.
  • Determination of disinfectants with Oxycon reagents following the DPD method.
  • Determination of free and bound chlorine, chlorine-dioxid, ozone, iodine, bromine, cyanuric acid, dissolved iron, dissolved aluminium and pH-value.

Chematest 20N(Data Sheet)Flyer Chematest 20N

CONDUCTIVITY
Monitor AMI Solicon4
For monitoring conductivity in a wide range (0.1 microS/cm to 100 mS/cm) in potable water, effluent and cooling water.

  • 4-Electrode platinum conductivity sensor with built-in temperature probe.
  • Excellent stability and fouling resistance.

Complete system mounted on PVC panel including:

  • Transmitter AMI Solicon4
  • Flow cell M-Flow PG.
  • Swansensor Shurecon P with integrated temperature sensor (Pt1000).

Factory tested, ready for installation and operation

Monitor AMI Solicon4(Data Sheet)Flyer Influence Of Temperature On Electrical ConductivityEinfluss Der Temper Tur Auf Die Elektrische Leitfaehigkeit

Oxygen (dissolved)
Monitor AMI Oxysafe
Monitor for continuous measurement of dissolved oxygen in potable water and effluents

Range: 0 – 20 ppm or 0 – 200% saturation
Automatic air pressure compensation
Automatic temperature compensation

Complete system mounted on PVC panel including:
Transmitter AMI Oxysafe

  • Power supply: 100-240 VAC, 50/60 Hz
  • Flow cell M-Flow M40.

Factory tested, ready for installation and operation.

Monitor AMI Oxysafe(Data Sheet)

pH
Monitor AMI pH/mV:pH/mV
Monitor for continuous measurement of pH or redox (ORP) in potable water and effluents.

Complete system mounted on PVC panel:

  • Flow cell M-Flow 10-3PG with temperature sensor (Pt1000).
  • Factory tested and calibrated. Ready for installation and operation.
  • Dual channel option available.
  • Transmitter AMI pH-Redox in a rugged aluminum enclosure (IP 66).

Monitor AMI pH/mV:pH/mV(Data Sheet)

Redox (ORP)
Monitor for continuous measurement of pH or redox (ORP) in potable water and effluents.
Complete system mounted on PVC panel:

  • Transmitter AMI pH-Redox in a rugged aluminum enclosure (IP 66).
  • Flow cell M-Flow 10-3PG with temperature sensor (Pt1000).
  • Factory tested and calibrated. Ready for installation and operation.
  • Dual channel option available.

Monitor AMI phmv-phmv m flow(Data Sheet)

Phosphate
Analyzer AMI Phosphate HL
Colorimetric process analyzer for the automatic, continuous measurement of phosphate in boiler water, district heating and cooling water.

  • Measuring range: 0.1 to 50 ppm (mg/L) PO4
  • Based on colorimetric measurement principle.
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • No interferences with silica
  • Control of sample flow and reagent fill level.
  • Factory tested and calibrated. Provides immediate results.

Phosphate HL(Data Sheet)

Analyzer AMI Phosphate-II
Colorimetric process analyzer for the automatic, continuous measurement of phosphate in potable water, effluents and cooling water.

  • Measuring range: 0.01 to 10 ppm (mg/L) PO4
  • Based on colorimetric measurement principle according to ISO 6878
  • Complete system including measurement and control electronics, photometer, flow indicator, reaction chamber, reagent dosing system and reagent containers.
  • No interferences with silica
  • Control of sample flow and reagent fill level.
  • Automatic cleaning module available as option.
  • Factory tested and calibrated. Provides immediate results

Phosphate II(Data Sheet)

TURBIDITY
Monitor AMI Turbiwell 7027
High precision, non-contact nephelometer based on ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of turbidity in pure water, potable water, surface water treatment and effluent.

  • Range: 0.000 to 200.0 FNU with a precision of ± 0.003 FNU or 1% of reading.
  • Turbidimeter with sample chamber and valve for chamber drain.
  • Optional sample degasser for the prevention of interfering bubbles formation in the sample.
  • High precision secondary standards for quality assurance.

Monitor AMI Turbiwell(Data Sheet)Flyer AMI Turbiwell LowArticle TurbiwellEignungsnachweis AMI Turbiwell

Monitor AMI Turbitrace
High Precision Nephelometer complying with ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of low level turbidity in pure and ultra pure water.

  • Range: 0.000 to 100.0 FNU with a precision of ± 0.001 FNU or 1% of reading.
  • Programmable automatic zero point measurement for drift compensation by integrated sub-micron particle filter.
  • Monitoring of sample flow and sensor fouling with alarms.
  • High precision secondary standards for quality assurance.

AMI Turbitrace(Data Sheet)Flyer AMI Turbitrace

Monitor AMI Turbitrack
High Precision Nephelometer complying with ISO 7027 (EN 27027, DIN 38404) for the continuous measurement of low level turbidity in pure water with up to 10 bar.

  • Range: 0.000 to 100.0 FNU with a precision of ± 0.001 FNU or 1% of reading.
  • Turbidimeter with sample chamber purge and flow controller.
  • Monitoring of sample flow with alarm.
  • High precision secondary standards for quality assurance

AMI Turbitrack(Data Sheet)Flyer AMI Turbitrack